Anti-Termite Reticulation System in Jaipur

Quick answer

SKUAS installs anti-termite reticulation in Jaipur on scheduled project visits from Delhi. We lay TermiPore porous pipe along the plinth and wall lines of new villas, houses and buildings, charge it with Envu Premise SC at the IS 6313 dose, and refill it every 2 to 3 years through junction boxes, so there is no drilling once the floors are laid.

TermiPore porous pipesEnvu Premise SC termiticideDosage as per IS 6313Written SKUAS warrantyServing since 2012

Jaipur keeps expanding outward through JDA schemes and private townships. Jagatpura, the Mansarovar extensions, Vaishali Nagar and the stretch along Ajmer Road are full of new independent houses and villas, while Tonk Road and Sikar Road are seeing apartment projects, with farmhouses on the edge of the city. Each of these passes through the same plinth stage, and that is where a reticulation system belongs.

The soil is the big difference from NCR. Large parts of Jaipur sit on sandy, loose soil that drains fast and dries out in the long, hot summer. Subterranean termites live deep in such ground and come up wherever they find moisture and cellulose: under kitchens, beside water tanks and against wooden frames. A refillable pipe barrier lets us renew the treated soil under those spots on a fixed schedule.

Termite risk in Jaipur: what we plan for

Loose, sandy soil

In sandy ground, a liquid poured once from the surface can sink and spread unevenly. TermiPore pipe releases the emulsion through micro-pores along its whole length, right at the wall line where it is needed. We still compact the fill and lay the pipe on a levelled bed so it does not shift when the floor is cast.

Hot, dry summers and a short monsoon

Jaipur has a long, very hot summer and a shorter monsoon than the NCR plains. Termites retreat deep in the dry months and move closer to the surface after the rains. A refill planned soon after the monsoon puts fresh chemical in the soil at the time termites are moving near foundations.

Villas and farmhouses with large gardens

Many homes on Ajmer Road, in Jagatpura and along Tonk Road sit on big plots with lawns, trees and drip irrigation. That watered soil next to the walls is where termites concentrate. We run pipe along garden-facing walls and around outhouses, and keep junction boxes visible above the lawn line.

Stone floors and carved woodwork

Jaipur homes often combine stone flooring and cladding with carved wooden doors, jharokha-style windows and wooden ceilings. Stone floors are costly to drill and refinish, so treating the soil through refillable pipe spares the floor while keeping termites away from the woodwork above it. It also avoids the dust and patchwork that drilling leaves on polished stone.

Reticulation pipe layout along boundary and internal walls with junction boxes, and a cross-section at the plinth
Typical layout we install in Jaipur: porous pipe along every wall line, refilled through junction boxes outside.

Pipe and chemical we use in Jaipur

TermiPore porous pipe cross-section showing micro-pores on all sides

The pipe we install

TermiPore porous pipe

Made in Vadodara, Gujarat, India from a thermoplastic elastomeric compound with a honeycomb micro-pore wall. Termiticide seeps out evenly through micro-pores on all sides, unlike hand-drilled PVC that leaks at a few holes. The manufacturer rates pipe life at 30 to 50 years (manufacturer estimate).

Sizes, specs and how to spot genuine pipe
Envu Premise SC termiticide 1 litre bottle

The chemical we charge it with

Envu Premise SC

Imidacloprid 30.5% SC from Envu (formerly Bayer Environmental Science). It is odourless and non-repellent: termites cannot detect it, carry it back to the nest and pass it on to the colony.

Why we use Premise SC

Reticulation plans in Jaipur

PipeGuard Basic

Boundary protection for compact homes

  • Coverage: External boundary (plinth perimeter) only
  • Pipe: TermiPore 17.5 mm (green stripe)
  • Refill points: Junction box every 25 to 30 m
  • Chemical: First charge with Envu Premise SC
  • Warranty: Up to 3 years written SKUAS warranty
  • Refill: Refill recommended every 2 years
  • Flow test before covering
  • Installation photos

Rate: shared after a free site inspection

Get my estimate

PipeGuard Max

Builders, societies and commercial sites

  • Coverage: Boundary, internal walls and under-floor grid
  • Pipe: TermiPore 19.5 mm premium (red stripe)
  • Refill points: Brass-nipple junction boxes every 20 m
  • Chemical: First charge with Envu Premise SC
  • Warranty: Up to 10 years written SKUAS warranty with AMC
  • Refill: Scheduled refills under AMC
  • Pressure and flow test log
  • As-built drawing for handover
  • Annual inspection report

Rate: shared after a free site inspection

Get my estimate

Every site is different. Soil, plinth size, wall layout and access change the final figure, so we confirm the exact rate after a free site inspection. Warranty is SKUAS's own written service warranty; the period depends on the plan and site conditions.

Free estimate in 30 seconds

Reticulation System Estimator

Get the pipe length, number of refill points, chemical quantity and the right plan for your building. Our engineer then shares the exact rate on WhatsApp or call.

Buildings we protect in Jaipur

Villas in JDA schemes and townships

Room-wise loops and outer plinth lines for new villas in Jagatpura, Vaishali Nagar and the Mansarovar extensions.

Farmhouses on Ajmer Road and Tonk Road

Pipe around the main house, staff quarters, stores and wooden pergolas spread across large plots.

Apartment buildings

Basement and ground slab lines for new residential projects, coordinated with the builder's construction schedule.

Factories in Sitapura and VKI

Boundary and column-line pipe for units in Sitapura Industrial Area and Vishwakarma Industrial Area, planned around machine foundations.

How a Jaipur installation runs

Jaipur projects are handled by our central installation team, which travels from our New Delhi head office for scheduled projects; we plan visits around your construction milestones. Share your drawing and expected plinth date early, and we will confirm the trip so pipe laying, the flow test and the first charge all fit into the window before your floor PCC.

  1. Free site visit. We measure the plinth and mark wall lines on your drawing.
  2. Pipe laying. TermiPore pipe on a levelled bed along every planned line, joined to junction boxes.
  3. Flow test. Water is pumped through each loop before the pipe is covered.
  4. First charge. Premise SC at the IS 6313 dose of 5 L per m² of floor area.
  5. Handover. Photos, port layout and your refill reminder schedule.

Chemical quantity per charge

Chemical quantity per charge (IS 6313 dose of 5 L per m² of floor area)
Floor areaDiluted emulsionPremise SC concentrate
500 sq ft≈ 230 litres≈ 490 ml
1,000 sq ft≈ 465 litres≈ 980 ml
1,500 sq ft≈ 695 litres≈ 1.5 litres
2,000 sq ft≈ 930 litres≈ 2.0 litres
3,000 sq ft≈ 1,395 litres≈ 2.9 litres
5,000 sq ft≈ 2,325 litres≈ 4.9 litres
10,000 sq ft≈ 4,645 litres≈ 9.8 litres

Areas we cover in and around Jaipur

Malviya Nagar, Mansarovar, Vaishali Nagar, Jagatpura, C-Scheme, Raja Park, Bani Park, Civil Lines, Shyam Nagar, Sodala, Nirman Nagar, Vidhyadhar Nagar, Jhotwara, Pratap Nagar, Sanganer, Durgapura, Gopalpura, Jawahar Nagar, Tonk Road, Ajmer Road, Sikar Road, Kalwar Road, Muhana, Sitapura, Vishwakarma Industrial Area, Bagru.

Frequently asked questions: reticulation in Jaipur

As a scheduled job. You send the drawing and your contractor's timeline, we review it and arrange a site inspection, and the team returns for pipe laying when the plinth is ready. Refills every 2 to 3 years are booked the same way, as planned visits.
Not when it is installed correctly. Because sand drains quickly, we lay the pipe on a compacted, levelled bed close to the wall line and charge it at the full IS 6313 dose. Keeping to the refill schedule is important here, since sandy soil does not hold moisture for long.
Yes. Each structure gets its own pipe loop, and loops can share junction boxes where buildings are close together. Wooden gazebos and decks resting on soil can be treated around their footings. We work out the full layout after walking the whole property.
Ideally while the foundation is being dug. That gives us time to plan the trip from Delhi and mark wall lines and junction boxes on your drawing. The pipe itself goes in after the plinth beam, before the earth filling and floor PCC.
Yes. The pipe sits in the soil below the PCC, so the flooring above makes no difference. That is a real advantage for Jaipur homes with stone floors: refills go in through junction boxes outside, and the stone does not have to be drilled or lifted.

Aam sawal (Hinglish)

Hamari installation team aapke construction schedule ke hisaab se scheduled visit par aati hai. Plinth ya PCC ki date pehle se bata dijiye.
Haan, pipe dabayi hui ret ke bed par lagta hai aur IS 6313 ki poori dose di jaati hai.
Nahi, refill bahar ke junction box se hota hai.

Building in Jaipur? Book a free site inspection

Our engineer visits, measures the plinth and shares an itemised quote. The best time is before the plinth beam or floor PCC.